Diving apparatus
- Open the cylinder valve and check that the pressure is at least 20 bar.
- Loosen the diffuser holder and remove the diffuser, refit the diffuser holder. Remove the cover. If necessary, clean and rinse the cover and diffuser with fresh water.
- Remove the bellows weight.Press the button on the bellows plate, while pulling the weight downwards on the valve block.
- If necessary, clean and rinse the exterior of the IS-MIX with fresh water and make sure the shut-off valve is closed/switch-over valve in bail-out position.
- Remove and clean the breathing hoses and full face mask.- Loosen the breathing hoses' holders that are fixed to the rubber tensioners on the cover - Loosen the breathing hoses' bayonet couplings by turning the hoses so that they are at right angles straight up from the IS-MIX and then pull straight out to the side.- Rinse the hoses inside with fresh water. Rinse the mask inside with fresh water.
- Remove and clean the bail-out breathing valve and microphone with fresh water.
- Remove the canister and drain the absorbent.Take off the canister lid, remove the canister and drain it of absorbent. If necessary, clean and rinse the canister with fresh water.
Note: WARNING!To prevent water from entering the dosage system, a by-pass must always be made while internal rinsing of the canister housing occurs.
- If necessary, clean and rinse the canister housing internally with fresh water during continuous by-pass operations, avoid aiming the powerful jet in the canister stub.
- Rinse the inside of the bellows with fresh water, the bellows will rise and water will drain through the surplus valve. Clean and rinse the canister lid with fresh water.
- Empty the bellows and canister housing.Raise the IS-MIX let the water run out of the bellows and canister housing.