Lubricate a new O-ring, 88 501-951, sparingly with Krytox and fit it on the microphone plug, 88 509-952. Remove the locking clip and the old microphone blind plug if needed and fit the microphone plug in by hand. Be careful not to refit the new plug at an angle. Fasten the plug with the clip.