Warning indicator
This test is made to check that there is breathing resistance during warning.
Breathing resistance
- Open the breathing circuit on the full-face mask or mouthpiece.
Wait until the warning is activated (if it is not already activated).
- Lift the bellows slowly to position 3. Check that the bellows remain at position 3.
- Breathe gently and check that there is breathing resistance during inhalation.
- Repeat steps 2-4 twice to ensure that the breathing resistance warning is working and that it can only be sensed during the first inhalation phase.