Donning of IS-MIX and DPX
The diver dons the IS-MIX apparatus according to standard procedure.
- Adjust the IS-MIX safety belt and connect the diving hose with its relieving loop to the IS-MIX safety belt.
- Disconnect the parked hoses on the IS-MIX pressure gauge as well as on the PX+ regulator (if connected).
- Connect the PX+ quick coupling hose to the IS-MIX pressure gauge and the DPX hose on the IS-MIX bail-out regulator to the PX+ bail-out quick coupling.
- Put the PX+ regulator in one of the pockets on the buoyancy compensator.
- Close the bail-out cylinder and the IS-MIX gas cylinder.
- Pull the reserve valve.
- Perform a by-pass and check that the pressure gauge shows <20 bar.
- Perform a by-pass and check that the warning is activated within 55 +- 15 sec on the IS-MIX.
- Set the switch-over valve in bail-out position and test the bail-out breathing valve. Then return the switch-over valve to rebreathing position.
- Don full face mask (if not done) including communication.